Tikfollowers

Mainsail pause macro gcode not working. how do you alter it's behaviour? e.

That's a feature that allows you to replace any existing command with a macro while still being able to use the existing command under a different name. PreviousLocalizationNextMacro Prompts. Fluidd requires some basic configuration to be applied in order to function correctly. cfg. Click the gear icon ⚙️ to open PrintNanny OS settings. The installation instructions call out this kind of issue: Note: Make sure you don't currently have any macros that provide the same Aug 31, 2022 · SKR MINI E3 v3. ” For Mainsail: “You can show and hide G-Code macros in the interface settings. Last updated 1 year ago. Alternatively you can add saving time and disabling timeout Oct 8, 2023 · variable_verbose_enable: True # Set to True to enable KAMP information output when running. pause_resume is not defined in config. So you can use it however you like, but the May 8, 2023 · Jul 3, 2023. Restart Cura for the changes to take effect. The values are the same as the default. BASE_CANCEL_PRINT. I can see the build plate move into position and pause for that . M190 S{BED_TEMP} ; wait for bed temp. Features . 0. Important: The tab / spaces before the gcode is required. 3 MB) klippy. Jan 30, 2021 · Printer is a Voron V0 cxy with SKR Mini E3 2. [gcode_macro START_PRINT] gcode: {% set BED_TEMP = params. Every time I pause the printer the toolhead goes to X maximum and picks up the klicky probe that is there on a magnet. RESUME. Cancel don’t exist at all. Then it would be easy to generate an appropriate filament change sequence of gcode commands. That would pause immediately and allow filament change. Save the config after completion The profile is saved and available after the restart. If you don't have that macro, you need to create it. cfg and place it below your mainsail include. A number of macros are pre-defined in the example configurations but a lot more is possible. 2, and change 0. Print start dialog. To get around this, gcode_macro to the rescue: Drag the layer slider on the right to select the target layer. HEIGHT - Z height (in mm) to run the command. 4. If one requires a less common G-Code command Position for PAUSE : front left (10x10 mm) First copy the complete _CLIENT_VARIABLE macro from the mainsail. I had a pretty decent adaptive mesh macro that I spent a good week writing myself and used for months, and I ditched it immediately for this one after giving it a good read through. This isn't really relevant for PAUSE, but let's pretend the PAUSE command accepts a BED parameter for the bed temperature: So it would be run like PAUSE BED=60 or something. Macros are prefixed with gcode_macro followed by a space and then then name of the macro. Haven't bitten the bullet yet and transitioned to Mainsail. I assume that PAUSE always called the macro from mainsail. gcode_macro pause is not defined in config. Position for PAUSE : front left (10x10 mm) First copy the complete _CLIENT_VARIABLE macro from the mainsail. This is a macro that serves as a place to store variables that all the RatOS macro's refer to when they're executed. g set the location the head should go to when Paused? Post your gcode_macro PAUSE macro. 7 Mainboard and mainsail running on a Raspberry Pi 3+ with a klicky probe that sits at the maximum position of X. is_paused gcode_macro pause is not defined in config. I'm not at my computer, so I don't know which command it was, but let's say it's like M123, then you would create a macro named that, and that macro just calls the pause command. Mainsail can display thumbnails in the file browser and as previews in the print status. Now: Do a bed mesh calibration from the mainsail and give the name of the profile before starting. Sometimes after resuming it causes unexpected behavior such as: moving Z below the print, crashing into it (what the attached log represents) moving Z way above the print, extruding into thin air. cfg below. Free, secure, and unlimited remote access to your full Mainsail web interface built by the maker community. It works great and it's a lot less confusing to get it working. pause_resume. cfg] Save the file and restart the firmware. In MainsailOS they are stored by default in mainsail. When I try to run the macro I am receiving " gcode command pause already registered ". Klipper default pause/resume do almost nothing besides saving/restoring position. toolhead. LOAD_FILAMENT and UNLOAD_FILAMENT are also hidden. #6. Pasting your printer. I tried to do multi layered prints with my Ender 3pro and cura I followed cheps video. Macros are an essential tool for configuring and managing Klipper. This explains why there is two different Macros set Sep 15, 2020 · Loading Mainsail with these macros as-installed produces the following error: "Existing command 'CANCEL_PRINT' not found in gcode_macro rename. Thanks, Craig I have added the pause and resume macros and they work great, just not when I add them to the g code. I am trying to set up a pause/ resume macro provided by ellis3dp. To add these scripts, click on Extensions > Post Processing > Modify Gcode. After the macro declaration, we need to define a gcode: section for the macro. Since they're gcode variables you can change them on the fly, for example from your slicer's custom gcode sections: SET_GCODE_VARIABLE MACRO=RatOS VARIABLE=relative_extrusion VALUE=True. The most commonly accessed settings are accessible via the cog icon in the cards header and allow you to customize the preview’s behavior. cfg" somewhere in the printer. [gcode_macro LEDON] gcode: SET_PIN PIN=LED VALUE=1. Runs abritrary, user-provided g-code commands at the user-specified layer or height. Apr 28, 2024 · Introduction to Conditions and Looping. It'll indicate the Klipper firmware to take a snapshot of the ongoing print. Required The following configuration elements are required and must be configured for Mainsail to function properly. recommended for Raspberry Pi users. Fast way (mainsail. klipper, mainsail, usb webcam, auto render is on, tried with and without save frames. Pasted my mainsail. gcode: TURN_OFF_HEATERS. May 2, 2023 · Both sets of documentation that you linked say that it’s possible. This installment of our Mini-Tutorial on G-Code Macros is all about three important constructs in G-Code Macro Programming: – GOTO: The ability to jump around arbitrarily in G-Code. Here is an example. As followed in tutorials, i've deleted the cura start gcode and inserted START_PRINT under the machine settings of Cura then in mainsail. 15 KB. But there are two points that i do not understand: 1: M600 is called directly from the gcode file. gcode_macro RESUME is not defined in config. Select Add custom G-code. Click Edit Settings Files in the left-hand menu, and select klipper/printer. Cura on the other hand appears to skip native gcode temp settings when a Klipper start macro is added. homed_axes %} G28. Hide macros, outputs or fans. So basically it works. # Alternatively, import this file by adding. Useful Klipper Macros. I have a STM32F401 chip. To keep the project going he invests his free time, almost every day. – IF: The ability to make decisions based on Conditions. 8 F2700 G1 Z {Z} G90 G1 X {X} Y {Y} F3000 G91 G1 E-50 F1000 G90. cfg but don't know what to do next. After that uncomment the needed variables or all. pause_delay: 0. I've opened the sliced gcode and can see the START_PRINT at the start of the code. I need to test this but I am quite certain that this was the problem. log (5. Pause/ Resume Macro Difficulties. Open PrintNanny OS settings. It can automatically follow the print progress and provide you with information about the currently executed moves. 4 profile. It allows macros in Klipper to trigger dialog prompts to interact with the Firmware and will enable the user to choose between options or to close the dialog again in case it's no longer needed. cfg: Mar 4, 2019 · [gcode_macro M600] default_parameter_X: 50 default_parameter_Y: 0 default_parameter_Z: 10 gcode: PAUSE G91 G1 E-. gcode_macro cancel_print is not defined in config. cfg file and it appears to be the correct one from the klipper github. Copy and paste the Klipper setup code from Justin’s Github page in the macro file. Ensure your desktop/laptop and Klipper are connected to the same network. I would enter the I want to pause and what macroin this case m600. The important bit here is the rename_existing entry, this makes it so that the previous definition of CANCEL_PRINT is now called BASE_CANCEL_PRINT and can be called from your new macro. This will open PrintNanny OS's Mission Control dashboard. Raw. Once the underlying issue is corrected, use the "RESTART". CLEAR_PAUSE. I am using Cura with the default 2. It is important for this size to be a square, with equal size on Hyperlapse: This does not require you to add anything to the slicer. You can display the probed mesh, the Macros. 1. Type in the following command at the bottom of the file: [include macros. You can find more information at Macro Management. EXTRUDER_TEMP|default(190)|float %} # Start bed heating M140 S{BED_TEMP} # Use absolute coordinates G90 # Reset the G-Code Z offset (adjust Z offset if needed) SET_GCODE_OFFSET Z=0. It works by capturing a new frame at a regular time interval. com. I am at a total loss, I see the set_print_stats_info macro in the mainsail. # You can copy these entries into your printer. Klipper macros are always in the following format: [gcode_macro <macro_name>] gcode: <gcode>. # The following variables are for adjusting adaptive mesh settings for KAMP. log file. # These macros are required for Fluidd to correctly function. AndreKR: But it also seems that the homing issue is not resolved. This also works for other configuration sections including fans and outputs. My mainsail. Best thing would be if there was a pause gcode which only pause/resume without doing anything which works synchon as any other gcode command. Hello All, I have encountered an infuriating issue, and I believe it is with my pause_part_cancel macro. 1 second after every layer but I can't locate any video or images. Trusted Clients - read carefully A list of newline separated IP addresses and/or IP ranges that are trusted. Pause/Resume - Change Pause location. Feb 11, 2022 · Klipper built-in gcode_macro [ACTIVATE_EXTRUDER] no longer functions as previous. Nov 10, 2022 · A workaround would be to call the Klipper start macro filament custom start code section instead or alternatively not use a start macro at all, at least not for temp control. Open the printer. !!! ## ## Customization: ## 1) copy the gcode_macro _CLIENT_VARIABLE (see below) to your printer. May 18, 2023 · Basic Information: Printer Model: Custom MCU / Printerboard: SKR Pico 1. Mar 20, 2023 · today I found the mainsail-config when searching why I can't edit the mainsail. printer. This makes it easier to work with different surfaces and flexplates. page’s code, I could only found " * CANCEL_PRINT macro not found in configuration. The double pause is because you're including both the mainsail-config macros and these macros at the same time. Question: if you send a "PAUSE" to the printer during a print. It keeps giving the "extruder temp to low" after the probe movement is finished, and stops. So, the macro that has pause at layer. g. Macro Prompts. The custom G-code will be inserted before the selected layer is being printed. G28 Z ; Home Z. txt Oct 22, 2023 · I tried Installing your klipper-macro set, following the install-instructions given in this repo. Blake100 February 11, 2023, 10:26pm 1. as there is also a M600 i tried to modfy my unload Filament macro to work together with the PAUSE from there, they use the 'printer. Printer is halted". 3 KB) Creality Sonic Pad Update Since July 11, 2023, Creality seems to have released a firmware with a newer Klipper version. We would like to show you a description here but the site won’t allow us. log Fill out above information and in all cases attach your klippy. Indirectly, the dashboard layout can also be customized through Mainsails macromanagement. cfg is read only, not read only on my other Klipper printer. # this line into your printer. Fluidd’s Gcode viewer provides a 2D-visualization of the currently selected layer. For KlipperScreen: “As you probably already noticed, you can show and hide the gcode macros in the interface settings, but you can also hide gcode macros by prefixing the name with an underscore. Dec 14, 2023 · But problem 1, the repeating of the last few GCode lines I could not solve. cfg file like the header area? Hi, I installed Klipper Mainsail and Bold marked part of code throwing errors. I think for Cura, I had to just create a macro for whatever gcode it used. klippy. Hey, I am running Klipper/ Octoprint on my Voron 2. Also, SuperSlicer with Klipper G-Code flavor inserts a ACTIVATE_EXTRUDER method whenever there is a change in the extruder, so this is also broken. cfg created a START_PRINT macro but for some reason the macro isn't starting once I start the print. On this page. cfg) and Moonraker ( moonraker. Behavior has been confirmed by at least one other Voron Discord member. Right-click on the orange plus icon. [gcode_macro _CG28] gcode: {% if "xyz" not in printer. 0 running Mainsail on Rpi3b+. It's just good design. Gadget, OctoEverywhere's free and unlimited AI print failure detection Listen, I love macros, and I love writing my own macros. 7 KB) webcur2010 August 31, 2022, 2:59pm 2. cfg and only need to be included in printer. More infos can be found here. Feb 3, 2023 · This used to work in some versions before: Do a bed mesh calibration from the mainsail and give the name of the profile before starting. [gcode_macro PAUSE_PRINT] gcode: PAUSE {rawparams} Adding {rawparams} after the command tells it to forward along any parameters to that command as well. Macros are compatible with Klipper only. Copy the code under the Define the Gcode Macro section. I just modified your HEAT macro to default to 200 but allow the option to select a different value in the interface, or just call the macro Welcome to the Ender 3 community, a specialized subreddit for all users of the Ender 3 3D printer. Pause/Resume Not Working Correctly. Reload to refresh your session. cfg file. Help me guys! Of course, I put macros on ‘fluidd. This is of course very usefull with a full plate where one item fails (comes from plate, etc) so you can exclude it, and print can continue without printing filament in the airand making a mess Mainsail requires a minimum configuration to function properly and will display a warning at startup if the required parts are not found in your configuration file(s). I found a way, just put. log. cfg - Pastebin. It means take the existing (built-in) RESUME command and rename it to RESUME_BASE. After that we need to enter the needed values. MainsailOS. Dec 6, 2022 · Follow the steps below to configure the plugin for your Klipper 3D printer, and experience remote 3D printing. Again, they are violating the OSS license and making money off the work of others. cfg ## 2) remove the comment mark (#) from all lines ## 3) change any value in there to your needs ## ## Use the PAUSE macro direct in your M600: ## e. Explore the sample-macros. PAUSE. Did you know, that you can also hide G-Code macros by prefixing the name with an underscore? MY_AWESOME_GCODE appears in your interface settings, _MY_HELPER_CODE does not. 3. This document provides information on implementing G-Code command sequences in gcode_macro (and similar) config sections. You signed out in another tab or window. gcode_macro PAUSE is not defined in config. Instead, Klipper prefers human readable “extended G-Code commands”. – WHILE: The ability for G-Code to perform repetitive tasks. 2 klippy. Trusted by over 145k makers, our worldwide server network provides instant loading and full-frame rate webcam streaming while keeping your access secure and private. <gcode>. My understanding is that if you have a screen attached you can generate a menu and stall gcode execution while waiting for user input. cfg and therefore not my custom macro, which included the command to switch off/ on the sensor. I'm sensing the runout using the RPI pin GPIO26 and I'm using this example Macro config for the M600 (I added the idle timeout line): [pause_resume] [gcode_macro M600] gcode: {% set X = params. Here's my macro: [gcode_macro START_PRINT] gcode: Mar 22, 2021 · In the config file we first need to define the macro. cfg is not needed When pasting code or config snippets use the code tags </> in the menu above Describe your issue: I setup a basic start print macro based on what I found on the Klipper Attempting to put a wipe into my start gcode, which works, but when I go to print z doesn't go to where it needs to be based off the probe offset(I think that's right). Jan 16, 2023 · Basic Information: Printer Model: Ender 3 V2 MCU / Printerboard: Creality 4. cfg; #. can_extrude' to check if the hotend temp is high enough to extrude. Click the PrintNanny OS link in the Actions & Quick Links menu. I recently added a filament runout sensor to my Octoprint/Klipper setup. This allows you to have a macro that redeclares an existing command but is still virtual_sdcard is not defined in config. G28 X Y; Home X Y. All from the Klipper interface . Useful to add an extra gcode line or two to an existing command. 11 with the following for the Start GCode: And this is my STAR_PRINT macro in my printer. with a different park position front left and a minimal An ABS filament change won't work very well at those temperatures. My pause/resume macros work as a pair. Feb 12, 2021 · PAUSE, RESUME and CANCEL_PRINT GCODE macros are defined in pause_resume. 5 # The amount of time to delay, in seconds, between the pause command # dispatch and execution of the runout_gcode. G-Code Macro Naming¶ Case is not important for the G-Code macro name - MY_MACRO and my_macro will evaluate the same and may be called in either upper or lower case. You can limit the scale by moving the sliders down or up. BED_TEMP|default(60)|float %} {% set EXTRUDER_TEMP = params. This is the same behaiviour of other UIs. Mainsail supports so-called presets. In the "Current Mesh" panel you get some values of the currently loaded mesh. Go to the Moonraker timelapse configuration website. Scraping it aswell Maybe the used editor indicates that. As this file references configuration for both Klipper ( printer. You switched accounts on another tab or window. ) in their standard configurations. May 27, 2022 · I am really missing the Region Exclude plugin from Octoprint in Mainsail, they have a nice Gcode preview, but no way to exclude something there. Have just enabled pause/resume in printer. Then click on Add a script, choose Create Thumbnail and fill in the size 32x32. Time lapse issues with mainsail. Exactly one of HEIGHT or LAYER must be specified. ". 0 Describe your issue: This is a general gcode macro question, not specific to my printer. The variable_user_pause_macro within mainsail. Nov 9, 2021 · I’m using Cura 4. Here's the docs on the topic. The least amount of setup. If any numbers are used in the macro name then they must Jan 21, 2020 · Using my PAUSE_MACRO followed by RESUME_MACRO is not always successful. conf ), each example contains a commment indicating which configuration file is being refrenenced. Save and close the file. Macro Management. Though I added CANCEL_PRINT macro, and just copy-and-pasted the initial setup. Trusted clients are given full access to the API. It is not a goal to support every possible G-Code command. In expert mode, macrogroups can be created that will be shown as panels on the dashboard. Sep 15, 2023 · I uncommented the [include mainsail. jasonheck said: Just built a new 2. 0 # Home the printer G28 # Move the nozzle near Jan 24, 2024 · IMO, none of the inserted gcodes is needed if you are using the default macros that Mainsail or fluidd are providing. [gcode_macro start_print] The next thing that is needed is the actual gcode to be executed. EDIT: Solved! Solution from DopeBoogie below: My guess is that Octoprint is overriding the PAUSE in the gcode while the one you send from the console runs the Klipper macro rather than the other way around. display_status is not defined in config. how do you alter it's behaviour? e. SAVE_GCODE_STATE and RESTORE_GCODE_STATE will function without the [pause_resume] enabler. Sep 15, 2020 · The default is 3 seconds. log (221. You can also just make up your own rules by creating a macro or delayed_gcode that you trigger by your own specifications, and having that macro run TIMELAPSE_TAKE_FRAME. Both IPv4 and IPv6 addresses and ranges are supported. Here, enthusiasts, hobbyists, and professionals gather to discuss, troubleshoot, and explore everything related to 3D printing with the Ender 3. Again, they have not released the sources for this and the other components as required by the GPL license. Mainsail is primarily developed and maintained by meteyou. variable_mesh_margin: 1 # Expands the mesh size in millimeters if desired. extruding lines so thick I would not believe possible in random directions. Feb 11, 2023 · General Discussion. command to reload the config and restart the host software. You signed in with another tab or window. Then when it pauses I can change the filament. Basically it stays where the wipe ends at and doesn't achieve proper squish for the print. Jul 15, 2023 · I’ve got an Ender3 with 4. Fluidd should warn you if these are not found in your configuration upon startup. log (425. Bubble: where/how to include it. cfg file for Klipper, a 3d-printer firmware. This feature needs the [respond] module of Klipper. Find out how to customize and enhance your printing experience with macros. Home if not already homed. The macro colors can be customized and macros can be displayed depending on the printer status. If you add parameters they will show up under a little drop-down next to the macro name. Example: Filament runout prompt. Its possible to manage your macros in Mainsail. This includes the name, size, min and max values, as well as the variance. If no arguments are specified it will display all currently scheduled g-code commands along with their associated layer or height. 4 and added Tap, but the extruder will not go back to the standard temp for printing, after lowering itself to 150 to use the probe. Will not z hop if this exceeds your max Z height. This is my cancel macro [gcode_macro CANCEL_PRINT] rename_existing: BASE_CANCEL_PRINT gcode: CLEAR_PAUSE SDCARD_RESET_FILE PRINT_END BASE_CANCEL_PRINT Sep 25, 2023 · after adding PAUSE RESUME CANCEL macros from the Mainsail website, Klipper shows me this error: Option ‘ {% if printer. This is my mainsail. #. You can sort, colorize or auto show/hide some macros in special printer states. Additional Commands¶ Klipper uses "extended" G-Code commands for general configuration and status. We only have one extrusion system with multiple extruder steppers. I think you could probably write your own macros that mimic the functionality. later and macro. I looked at the printer. MainsailOS is a prebuilt image for single board computers that already includes Mainsail, Moonraker and Klipper. To motivate him (☕🍺😜) there are several ways to support him: Patreon (recurring) GitHub (recurring or one-time) Ko-Fi (one-time) Please also support all of our maintainers and contributors. To configure the G-Code enter SET_GCODE_OFFSET Z=0. ; Auto Leveling. SDCARD_RESET_FILE. cfg does not execute as expected. Instead it prints on the bed. A line "rename_existing: BASE_PAUSE" in the Dec 12, 2022 · User still need to learn how to create macros at least for pause/resume/cancel functionality. cfg from the file drop-down. cfg in your printer. here is my klipper log Klipper log - Pastebin. Macros. cfg mainsail. After removing all old macros existing before in my config, and changing the prusaslicer settings accordingly, I still endet up with error: Existing command 'SET_PRINT_STATS_INFO' not found in gcode_macro rename Klipper’s goal is to support the G-Code commands produced by common 3rd party software (eg, OctoPrint, Printrun, Slic3r, Cura, etc. Open Cura slicer. This is useful to throw at the beginning of other macros. Can you please confirm behavior, whether or not it is function as designed or bug or if there are workarounds available? Thanks a lot. here is my moonraker log moonraker log - Pastebin. After reading and following several write ups that all say the same fairly simple instructions History. py and correctly save and restore GCODE state on pause and resume respectively. You can show and hide G-Code macros in the interface settings. ;Put printing message on LCD screen. (The "PAUSE, forced by pause_next_layer" message is coming from mainsail-config, not these macros). Are they saying I need to have the text "mainsail. In short, Prusa Slicer adds stuff that can't be removed or controlled. This document describes Moonraker-timelapse configuration. 2 to the offset you need. If one requires a less common G-Code command then it may be possible to implement it with a custom gcode_macro config section. In addition, you can limit the scale to the min/max values of the profile with the toggle switch. There you could even add a simple SET_PAUSE_AT_LAYER LAYER=xxx in your sliced gcode at the beginning and Klipper will do the rest. X|default(50)|float %} is not defined in config. Make sure you include the mainsail. If I hit the m600 macro that is created. Open the Cura Marketplace, and Install the Moonraker connection plugin. However, if you only interact with klipper through Mainsail, then there is no equivalent “wait Apr 6, 2023 · klippy. I created a one-line macro to move the nozzle to zero. On pause, moves the toolhead (z hops) up by 10mm, then moves the toolhead to the front for easy loading/unloading. Code above goes directly to idle timeout gcode. Macro status pause (should this macro be displayed, when the printer is in pause) Feb 3, 2023 · This file will contain all the information related to your macros. Thumbnails in G-codes list. For example, one might use this to implement: G12, G29, G30, G31, M42, M80, M81, T1, etc. M117 Heating M140 S{BED_TEMP} ; set bed temp. extruder. cfg’. . {% endif %} Ellis’ Print Tuning Guide. [gcode_macro M84] rename_existing: M84. . Insert the custom G-code into the newly opened window. Hidden by the interface. is_paused|lower’ is not valid in section ‘gcode_macro cancel_print’. It may be useful to # increase this delay if Octoprint exhibits strange pause behavior. Parking the toolhead, unloading filament, and awaiting instructions. Add again the same script with the size 400x400. [gcode_macro LEDOFF] gcode: SET_PIN PIN=LED VALUE=0. Will not allow you to accidentally execute pause or resume twice. Octoprint goes into pause mode Nov 2, 2022 · Configure the timelapse Macro for your Slicer This step will add a timelapse command in your Gcode files from the slicer. Then It starts printing but not on top of the other one. After this change resume still didn't work from Repetier-Server and I'm not sure why because the RESUME macro should have been called to restore the state, I will look into this more. gcode_macro resume is not defined in config. which has inputs if. You can add several commands at once, simply press Enter to insert a new line. gcode_macro CANCEL_PRINT is not defined in config. One will not work properly without the other. Save the config after completion The profile is saved always as Mar 19, 2022 · The following works for turning OFF the LED because when the print is finished it sends an M84 to disable the motors. cfg) The following configuration elements are required and must be configured for Mainsail to function properly. cfg] in my printer config, made it pause and now the idle position is X10 Y10. This is useful for debugging. They are often used for preheat & cooldown, but also execute normal G-Code. Here is my mainsail. All gcode_macros with the attribute rename_existing are hidden , because these are default Klipper Gcodes and these should be implemented in KlipperScreen itself with buttons already. 270 lines (208 loc) · 9. But the macro posted above in the top-level comment will not work without [pause_resume] because it uses variables that depend on it such as printer. Example: After the nozzle moves to the pause position, I want the nozzle to go to G1 Z0; in order to stop the nozzle from oozing. 2. Klipper gcode macros that I use with my Creality Ender 3. Nov 11, 2023 · I confirmed its not showing as paused, and it doesnt even have the be the same file. CANCEL_PRINT. The issue is: Every time I run an color change --my m600 macro is up to scratch-- It will behave normally. [gcode_macro PAUSE] rename_existing: BASE_PAUSE gcode: {% set X =… Pause / Resume . I added a custom command in the gcode thing in cura. gcode: You have to add a Post Processing Script to add "G-code thumbnails" in Cura. mx uq dz mo pp mo ic uj hb wh